Certifications
UL 1653
CSA C22.2 NO. 227.1:19
FT4 Fire Rating
UL & CSA Certified. Ledes flexible conduit pipe and fittings are UL and CSA certified for your peace of mind. If you have any further questions or would like more information, please don’t hesitate to contact us.
Concrete Tight. Ledes optimizes formulations and processes for concrete and underground environments, making quick and easy fixes a breeze thanks to its quick-connect fittings. Get the job done right, right now.
Impact Resistant. Up to 2.7J (2.0ft-lbf) anti-impact, won’t crack or break when installed. Experience worry-free security with this top-of-the-line impact resistance.
High Fire Rating. Made with brand-new, flame-retardant materials and engineered using cutting-edge processes, these assemblies offer unmatched fire protection, meeting the stringent standards of UL94.
Flexible & Strong. Up to 170 lbs of pull resistance, this band is super flexible and easy to bend with your hand – no tools required.
Trusted Partner. Proven leader in the construction industry with 15+ mega projects delivered worldwide and services 1,000+ companies across the US, CA, AU, UAE, and SA. Partner with the best, trust the expert.
Ledes Electrical Non-Metallic Tubing (ENT) is a corrugated flexible conduit used for electrical raceways, which is designed to replace EMT, flexible metal conduit, or other raceway systems in accordance with Article 331 of the National Electrical Code. It can be installed in concrete slabs, fire-rated interior walls, directly buried, and buildings.
Any ENT used shall meet the requirements of UL 1653 and NEMA TC-13 and shall be listed by Underwriters Laboratories, Inc.
Why You Need UL Listed Electrical Nonmetallic Tubing?
Unmatched Strength & Stability: Engineered for Quality & Performance
Experience exceptional electrical solutions with:
Choose Ledes for reliable and robust electrical installations.
Faster & More Efficient: Premium Materials for Superior Value
Enjoy the benefits of:
Experience the difference with premium materials from Ledes.
Supercharged Safety: Ledes ENT Conduit with UL 94V-0 Fire Resistance
Enjoy unparalleled safety with our:
Experience the next level of fire protection with Ledes.
Beyond Ordinary: The Hidden Dangers of Traditional Electrical Nonmetallic Tubing
Traditional electrical conduit, despite its apparent advantages, comes with hidden dangers:
Choose Ledes for reliable and safer electrical solutions!
Effortless Installation & Maintenance: ENT Flexible Conduit Made Easy
Experience the benefits of:
Get the convenience and efficiency you deserve with Ledes ENT flexible pipe.
Impact Resistant | 2.7J (2.0ft-lbf) |
Anti-Bend | Up to 4,448N (1,000 lb), No Cracked |
Pull Resistant | Up to 170 lbs |
Markings Test | No visible fading in oven test above 120°C for 7 days |
Fire Resistant | 2 Hour & 4 Hour Noncombustible |
Concrete Tight | UL Approved |
Tension Test | Up to 134N (300lbf) |
Permanency of Printing | Yes |
Rust & Sunlight Resistant | Yes |
Color | Grey, Blue, Red, Yellow or Customized |
Material | PVC |
Customized Services | Available |
Place of Origin | Dongguan, China |
Shipping | By sea |
Samples | Available |
Length | By Pack |
Markings
The following should be clearly and permanently marked on the ENT tube at intervals of not more than 1.5 m (60 in):
content:
a) the manufacturer’s name, trademark or other recognized identifier;
b) “ENT” type;
c) construction material “PVC”;
d) Metric and Imperial dimensions, such as 16 (1/2);
e) “FT4” when tested according to clause 7.3; CSA C22.2 NO.227.1-06 UL 1653 21
f) production code (date of manufacture);
g) “for residential attics 900 mm (3 ft) above the bottom of the ceiling joists” when the ENT material complies with clause 4.1.4;
h) In the United States, when the manufacturer has multiple plants producing electrical non-metallic bellows, identify the production plant. In Canada, subparagraph (h) does not apply.
i) In Canada, trade size 63 (2-1/2) should be marked “Canada Only”.
The smallest package of finished cut lengths, rolls or reels shall be marked with:
a) the manufacturer’s name, trademark or other recognized identifier;
b) “ENT” type;
c) construction material “PVC”;
d) Metric and Imperial dimensions, such as 16 (1/2);
e) the total length of the product in the package;
f) the manufacturer’s instructions for fixing the solvent connection fittings (this mark may appear on the packaging or in the accompanying booklet);
g) “For residential attics 900 mm (3 ft) above the bottom of the ceiling joists” when the electrical non-metallic bellows material complies with Section 4.1.4.
h) In Canada, trade size 63 (2-1/2) should be marked “Canada Only”.
Ledes ENT Coils – Blue Stripe
Size(in) | Part No. | OD(in) | ID(in) | Length Feet |
1/2 | LE-ULFC012 | 0.840 | 0.602 | Customized |
3/4 | LE-ULFC019 | 1.050 | 0.804 | Customized |
1 | LE-ULFC025 | 1.315 | 1.029 | Customized |
1-1/4 | LE-ULFC031 | 1.660 | 1.360 | Customized |
1-1/2 | LE-ULFC038 | 1.900 | 1.590 | Customized |
2 | LE-ULFC050 | 2.375 | 2.047 | Customized |
Ledes ENT Reels – Blue Stripe
Size(in) | Part No. | OD(in) | ID(in) | Length Feet |
1/2 | LE-ULFR012 | 0.840 | 0.602 | Customized |
3/4 | LE-ULFR019 | 1.050 | 0.804 | Customized |
1 | LE-ULFR025 | 1.315 | 1.029 | Customized |
1-1/4 | LE-ULFR031 | 1.660 | 1.360 | Customized |
1-1/2 | LE-ULFR038 | 1.900 | 1.590 | Customized |
2 | LE-ULFR050 | 2.375 | 2.047 | Customized |
2-1/2 | LE-ULFR038 | 2.866 | 2.469 | Customized |
Remarks: can be customized thickness and color
2-1/2 size for Canada only.
Price List
Get the full price list now by contact our sales team.
15+ major projects globally, such as The CHPE, A.B.Brown Station, Abu Dhabi UAE Al Dhafra PV2 Project, Melbourne Metro Tunnel, Macau Island Hospital project, and more.
We are proudly the first UL and CSA Certified electrical conduit pipe and fittings supplier in China; we boast an array of certifications, including ASTM, IEC, AS/NZS, ROHS, CE, and ISO.
Ledes would like to connect with customers face-to-face, that’s why we participate in many exhibitions. For example, we have participated in the IBS exhibition in Las Vegas many times, as well as the Canton Fair. In the future, we look forward to seeing you at the show!
Ledes is a professional PVC electrical conduit and fittings factory, and we have two different facilities located in China. Our product is UL, CSA, ASTM, IEC, AS/NZS, ROHS, and CE certified.
Yes, Ledes offers fully customized services for electrical conduits and fittings. Not only the color and size, we can customize based on your construction project.
Different size of conduit has different MOQs; if you talk about PVC conduit, it is generally 3,000 meters to 5,000 meters (9,850 ft to 16,500 ft), depending on size.
The general L/D is 15 – 30 days, but it depends on your quantity.
We shipped goods to Guangzhou or Shenzhen port. Let us know if you have any special requests.
We accept 30% T/T pre-paid, and the rest 70% needs to be paid before shipment.
Yes, we support sample services; contact us to claim your sample today!
You can contact us in 3 different ways: submit the contact form, send an email, or send us WhatsApp messages.